RA81 Rides Again! More problems.u
> 1. You've got two RH11's in the system, but (as far as I can tell)
> you've got no Massbus peripherals. Why not pull the RH11 system units?
Okay. I'd like to trim this down to one cabinet anyway.
>
> 2. Why is there no Unibus terminator at the end of the bus? (Or
> did you just leave it out?)
>
Oh, crap. There's the problem?
> 3. Are the M9300's sitting in RH11 system units? Just looking
> at your list above, I can't see why they'd be in the middle of the
> Unibus at all. M9300's are terminators, and unless there's a very
> special reason, they generally are only at the end of the bus.
Not sure, I stuck one on the end of the bus - everything started working!
>
> Generally, I think it'd be wise to pull all the unused cruft (esp RH11's!)
> and get the entire system in one box.
>
> "Not Interrupting" to me often indicates a problem with interrupt
> continuity. And if the interrupts aren't getting through, it's
> extremely surprising that any DMA to your RA81's is being done
> at all...
>
Now it didn't.
Apparently, someone moved some terminators around. Looks fine now!
> Tim.
>
Received on Sat Aug 23 1997 - 16:48:30 BST