argh, VAX DB-9 pinout?

From: Zane H. Healy <healyzh_at_aracnet.com>
Date: Wed Dec 15 02:54:29 1999

>I know that someone (Tony?) has already sent this to the list but for the
>life of me I cannot find it anywhere.
>
>What is the pinout of the MicroVAX 9 pin console port and what is the
>"correct" jumpering to wire it into a 9 pin serial port on a PC?
>
>--Chuck


It's in the VMS FAQ. http://eisner.decus.org/vms/faq.htm

The MicroVAX DB9 console connector pinout predates the PC-style DB9 pinout,
and uses a then-common (older) standard pinout, and uses the following
EIA-232-standard signals:

     1.Protective Ground
     2.Transmited Data
     3.Received Data
     4.Request To Send (RTS)
     5.Data Terminal Ready (DTR)
     6.Data Set Ready (DSR)
     7.Signal Ground
     8.Shorted to pin 9 on MicroVAX and VAXstation 2000...
     9....series systems, otherwise left floating.