> >I had trouble setting the clock on this system, maybe this is
> >the reason.
>
> If the RT-11 "TIME" command isn't incrementing, that has nothing to
> do with the TCU - it's an indication that the line time clock (60Hz
> for us) interrupt is somehow disabled.
>
> With the board in, does it respond at its standard addresses of
> 160770 - 160776? If so, then it's installed in the right sort
> of system.
>
> You ought to see the value at 160774 incrementing once per second
> if the clock is indeed ticking.
>
I haven't had chance to try that yet. I booted it a few times
after I got it, it runs RSX-11M, which I'm not overly familiar
with. Once I knew it basically worked I thought I would give
it a good cleaning and make an inventory of the parts (it has
a TK50 which I want to make sure works before I put tapes in
it). When I get it back up again, I'll look at the clock
again. Thanks for the information.
--
Dr. Mark Green mark_at_cs.ualberta.ca
Professor (780) 492-4584
Director, Research Institute for Multimedia Systems (RIMS)
Department of Computing Science (780) 492-1071 (FAX)
University of Alberta, Edmonton, Alberta, T6G 2H1, Canada