On 25 Jul, Bill Pechter wrote:
> I get the following errors at power up test:
>
> F...E...D...C...B...A...9...8...7...6...6...4...3_..2_..1...
>
> I know the 3_ 2_ means not tested... any info on the following minor
> errors...
On
http://www.bsdfans.org/ is a description of the Startup-messages of
a VAXstation 3100.
> ?E 0040 0000.0005
> ?B 0010 0020.0081
> ?6 80A1 0000.4001
> ?4 00D0 0007.0213
E CLK TOY clock
battery low?
B MEM Memory
???
6 SCSI-A SCSI-Controller B (Maionboard or daughtercard)
Not terminated? No devices found?
4 8PLN Option module (8 plane graphics)
No (proper terminated) monitor connected? (Yes, that can be detected.)
> I'm going to drop in a 1gb disk
You may have problems booting from disks > 1GB, depending on the PROM
version. So this may be an issue if your disk is 1GB + a few kB.
> I may throw a disk in for *BSD as well... I assume I can boot either
> drive.
Should work.
--
tsch??,
Jochen
Homepage: http://www.unixag-kl.fh-kl.de/~jkunz/
Received on Wed Jul 25 2001 - 06:40:11 BST