Honeywell 316 Question

From: Sellam Ismail <foo_at_siconic.com>
Date: Wed Feb 20 12:58:18 2002

On Wed, 20 Feb 2002, Owen Robertson wrote:

> I picked up a Honeywell 316 from a local scrap yard today. I gave the inside

Damn nice find! But you don't just "pick up" a Honeywell 316 ;)

> The power supply has no cord coming out of it. What is does have is a
> standard 3-prong plug sticking out of the back, just like the kind that
> plugs into the wall. So, can I just run an extension cord from it to the
> wall, or is there something more to it than that?

I would imagine this has some big fat caps that would need to be
brought up to nominal voltage slowly in case they need to be reformed. I
would definitely try to find a Variac to bring this up slowly over the
course of a couple hours, say 5 volts every 5 minutes.

Sellam Ismail Vintage Computer Festival
------------------------------------------------------------------------------
International Man of Intrigue and Danger http://www.vintage.org

 * Old computing resources for business and academia at www.VintageTech.com *