help needed: problem with UNIBUS access on my PDP-11/70
> However ... (I will check this again)
> RX11 in slot 41 --> hung and we know why.
> RX211 in slot 41 --> all OK and we know why.
> G7273 double grant in slot 41 --> THE HUNG IS BACK! Huh??
Very strange. You've got the G7273 in the right slots (C&D)? And
not upside-down? If it's inserted correctly, it can't help but pass
the grants through!
Received on Tue Jul 16 2002 - 03:44:08 BST
This archive was generated by hypermail 2.3.0
: Fri Oct 10 2014 - 23:35:01 BST