On Mon, 3 Jun 2002, Robert Schaefer wrote:
> Anyone know where I might be able to find out what the diag LEDs on my new
> '800 are telling me? I haven't been able to find much googling, but I might
> not be using the correct incantation. The LEDs stay on FD. I've tried with
> and without the red shorting jumper in the printer MMJ, with a vt320 on the
> printer MMJ, and with a vt320 on the DB25 port via an H8575-A both with and
> without the jumper. I do have a 3W3 cable to try the PMAGD-AA, but without
> a keyboard and mouse I really don't want to drag out the 21" monitor unless
> I have to.
>
> On a side note, what kind of keyboard and mouse does this use? Something
> compatible with an LK401, as in all I need is a little adapter box, or is it
> more complex than that?
>
> Bob
>
>
FD = Memory sizing complete = No memory found
Check you memory trees...
(table 47 in ek-d3sys-pm.ps (DEC3000 series manual))
Peter Wallace
Received on Mon Jun 03 2002 - 19:25:25 BST
This archive was generated by hypermail 2.3.0
: Fri Oct 10 2014 - 23:35:04 BST