Help needed:Setting up a KDA50

From: Megan <mbg_at_TheWorld.com>
Date: Tue Dec 2 18:20:57 2003

>Yes, a KFQSA controller creates up to three MSCP controllers;
>one for each device connected (in my VAX 4705A, which only HAS
>three drives.. it may support the full 7 drives..)

It does... I've done it (back when I was doing some work on having
KFQSA in a qbus pdp-11 and running RT-11 on the disks it was
attached to).

>also using that address, indeed. Most KFQSA's are configured
>to allocate as many controllers as needed, with the first one
>sitting at the MSCP-default address, soo..

They don't allocate addresses as you put disks on... you have to
configure the board using the SET HOST command on a uVaxIII
(which is what I did). I think you have to set the board to a
specific address to program it first, and once programmed you set
it back to the normal use address (there is a 4-switch switchpak
on the board)

                                        Megan Gentry
                                        Former RT-11 Developer

+--------------------------------+-------------------------------------+
| Megan Gentry, EMT/B, PP-ASEL | email: mbg at world.std.com |
| Member of Technical Staff | megan at savaje.com |
| SavaJe Technologies, Inc. | (s/ at /_at_/) |
| 100 Apollo Drive | URL: http://world.std.com/~mbg/ |
| Chelmsford, MA 01824 | "pdp-11 programmer - some assembler |
| (978) 256 6521 (DEC '77-'98) | required." - mbg KB1FCA |
+--------------------------------+-------------------------------------+
Received on Tue Dec 02 2003 - 18:20:57 GMT