MOTOR RUN VS. MOTOR START

From: Davison, Lee <Lee.Davison_at_merlincommunications.com>
Date: Thu Dec 4 15:25:59 2003

> The drawing does look as though it is in series with a
> second winding.

Then it would seem to be being used to create a rotating
magnetic field. In this case too samll a value will lead
to a reduction in full speed torque and possible speed
variations, and too large a value will reduce the low
speed torque (i.e. when the motor is running up). However
having said that the value will be a compromise anyway and
+/- 20% either way shouldn't hurt enough to notice.

Lee.