New here... Looking for PDP 11 / RSTS help
On Fri, 27 Jun 2003, Mark Firestone wrote:
> I have no problem building the system from the tapes (images)... that' s
> all fine. When you look at the HARDWR LIST (when you don't start
> timesharing) it sees the device (DZ0:) --but--
>
> when I try to connect via telnet, I just get
>
> "welcome to the PDP simulator" and then nothing.
Hmm, wasnt there a switch ("att -m dz0" comes to mind) you had to use
to change SimH's default behavior w.r.t. carrier detection? Basically,
although the connection works (you got the Telnet banner), the DZ11
does not report a valid carrier-detect signal to RSTS, meaning it
wont fire up a new terminal session.
I had the same problem in Ultrix-11 when this feature was first
present in SimH.
> Please help, if you can. I'm starting to lose sleep over this one. Oh
> yes, my wife did fill boxes with all sorts of stuff, like toilet roll and
> suave shampoo, so why my precious PDP 11/23 (and my TRS-80 Model II) had to
> be left behind I don't know. Women!
Next time, leave the wife in Phx. :)
--f
Received on Mon Jun 30 2003 - 03:32:00 BST
This archive was generated by hypermail 2.3.0
: Fri Oct 10 2014 - 23:36:09 BST