> Does anyone know how to use a DEMPR? Does it internally terminate each thinwire
> segment or not? I.e., do you run the end of the trunk directly into the DEMPR
> or do you T it like every other device on the segment?

You should run the trunk directly into the DEMPR.

> Do you need to enable/
> disable the thickwire uplink port (how?) or is it automatic? What does the
> button marked with a T in the circle do? What do the indicator lights mean?
> What happens if the DEMPR is powered down, do the segments simply partition with
> each segment remaining good by itself, or do the segments themselves become
> unusable?

If a segment becomes unterminated, the DEMPR will isolate it
automatically and turn on the indicator light. If the light is off, the
segment is fine. Unused ports will have the indicator on.

You should check this, but I think ;
 * The AUI uplink port does not need to be manually enabled
 * The T button will retest all isolated segments and reenable them if
   they test OK.
 * If the DEMPR is powered down, the segments are isolated but usable.

Nick.

-- 