MicroVAX I update part II the sequel
The leds and patch panel display show 7 through 1, with zero being
control passing to secondary bootstrap.
DAP leds Led display
on, on, on 7 microverify failed before
completing the data path
microsequencer test
on, on, of 6 error found on DAP module
on, of, on 5 Error found on MCT module
on, off, off 4 undetermined error in
DAP/MCT interface
off, on, on 3 microverify worked as expected
if bootstrapping was attempted,
bad memory was found
off, on, off 2 no boot device was found
off, off, on 1 unable to boot from selected device
off, off, off xxx control passed to secondary bootst.
This from the januaryu 1984 microvax I cpu technical description.