[VAX] KZQSA deaded?

From: Antonio Carlini <arcarlini_at_iee.org>
Date: Mon Mar 1 16:17:30 2004

> > P1=200002C0 P2=00000000 P3=30040000 P4=00000000 P5=00000000
> > P6=00000000 P7=00000000 P8=00000000 P9=00000000 P10=00000000
> > r0=00000054 r1=200001BF r2=00000000 r3=20140000 r4=200560E8
> > r5=20056124 r6=20063ACB r7=200002C0 r8=00000008 EPC=00000000
> > 04..03.. Normal operation not possible.
> >
> > >>>
>
> This looks like you don't have any terminators on the card.

Agreed. I had a VAX 4000-500 that was similarly upset by a
KZQSA that was missing a terminator on the unused connector.

Quite *why* the KZQSA code in the console behaves this way,
I do not know. I've booted plenty of MicroVAX 3100s with
missing terminators on the SCSI bus and never had a problem.

Antonio
 
-- 
---------------
Antonio Carlini             arcarlini_at_iee.org
 
Received on Mon Mar 01 2004 - 16:17:30 GMT

This archive was generated by hypermail 2.3.0 : Fri Oct 10 2014 - 23:37:03 BST