Commodore PET disk drive power-up error codes

From: Paul C. Mirams <paul_at_mirams.org>
Date: Mon Sep 13 13:43:26 2004

Here are the codes for the 8050/8250

http://www.devili.iki.fi/Computers/Commodore/8050/Service_Manual/page_5.html#Flash

The 6 flashes indicate a failure in the first bank of 2114 memory.

Paul

-----Original Message-----
From: cctech-bounces_at_classiccmp.org
[mailto:cctech-bounces_at_classiccmp.org]On Behalf Of Dave Dunfield
Sent: Saturday, September 11, 2004 1:27 PM
To: General Discussion: On-Topic and Off-Topic Posts
Subject: Commodore PET disk drive power-up error codes


Hi Guys,

Does anyone have information on error-codes that are flashed by PET disk drives
after power-up diagnostics fail.

I have a drive set which after powerup, enters into a state where it flashes the
POWER LED alternating with both drive LEDs (together) - It repeats this flash
cycle exactly 6 times, then pauses, then another 6 ... forever.

I assume it's a diagnostic failure - Can anyone tell me what it means?

Regards,
Dave

-- 
dave04a (at)    Dave Dunfield
dunfield (dot)  Firmware development services & tools: www.dunfield.com
com             Vintage computing equipment collector.
                http://www.parse.com/~ddunfield/museum/index.html
Received on Mon Sep 13 2004 - 13:43:26 BST

This archive was generated by hypermail 2.3.0 : Fri Oct 10 2014 - 23:37:29 BST