Ranges given are inclusive; i.e. a block listed as xxxx00-04 contains three words: 00, 02 and 04. Generally, QBUS18 versions of devices (where they exist) use the same addresses as the UNIBUS version; QBUS22 versions use the address as given here, with a "17" prepended. A few QBUS devices do not exist in UNIBUS form, and are listed in their own right: such cases can be detected by the device name, which is of the form 'xxV11'. All devices which use exactly the same block of address space as another device are listed on a single line, separated by " - ". Some blocks overlap, but are not congruent. These are indicated thusly: "*"; "**" indicates a double overlap, etc (but these are not entirely correct). "Reserved" means the block is specifically called out that way in a DEC document (source indicated). CPU registers marked as "11/73" also appear in the 11/83 and 11/84. CPU registers marked as "11/83" also appear in the 11/84. CPU memory management registers marked with "%" do not exist in CPUs with the '11/40' type memory management (11/23, 11/24, 11/34, 11/40, 11/60). 760000-6 Reserved (1) 760010-3776* Floating addresses 760150-2* IBV11-A 764000-7776**** Customer 764000* TR11/TR79 764004-66* LP11 (#0-#7) 764070-6* CMR11 764120-76* DRV11-J (#1-#3) 764200-376* PCL11 765000-776 M9301 - REV11 766000-7776* GT40 Bootstrap 767600-776* DR11-A/C 770000-76 Testers 770100-76 Reserved (0) 770200-372 UNIBUS map (11/24, /44, /70) (see note #0) 770200-376 UNIBUS map (11/84) (last pair responds, but not used) 770400-36**** LPS11 (26-34 unused) 770400-16*** AR11 770400-2*** ADV11-A/C 770420-2* KWV11-A/C 770440-6 AAV11-A/C 770450-56 Reserved (0) 770460-76 ADF11/LPA11-K 770500-676 DM11-BB (#1 - #16) 770700-76 KG11 (#1 - #8) 771000-776 UDC Functional I/O Units - ICR/ICS11 - IP11/IP300 771774 UDC11 - ICR/ICS11 771776 UDC11 - IP11/IP300 772000-36 GT40 (#1-#4) - VSV11 (#1-#4) - VT48 772040-72 RS04 772074-76 Reserved (1) 772100-36 MM11-LP Parity (#1-#16) 772140-46 UNIBUS Tester 772150-52 RQC25 - RQDX1 772154-56 Reserved (0) 772160-76 FP11 772200-16% Super I PDRs 772220-36% Super D PDRs 772240-56% Super I PARs 772260-76% Super D PARs 772300-16 Kernel I PDRs 772320-36% Kernel D PDRs 772340-56 Kernel I PARs 772360-76% Kernel D PARs 772400-6 KW11-W 772410-6 DR11-B (#1) 772420-6 DRV11-B 772430-6 DR11-B (#2) 772440-76 TU16/45/77 772500-12 OST 772514 Reserved (0) 772516% MMR3 772520-32** TM11 772520-36** TMB11 - TS11 - TQK25 772520-26** TSV05 772540-4 KW11-P 772546 ? 772550-66 Reserved (0) - XY11 772570-6 AFC11 772600-776*** VTV01 772600-76* PA611 Readers 772700-76** PA611 Punches 772760-76** NCV11 773000-776*** BM873-YB/YC - BM792 - M9301-xx - BDV11 - KTJ11-B ROM 773000-376*** BM873-YA - REV11 773000-76*** BM792-YA 773100-276*** MR11-DB 773100-76*** BM792-YB 773200-76*** BM792-YC 773300-76*** BM792-YD/YH 774000-376 DC11 (#1-#32) 774400-776*** DP11 (#1-#32) 774400-6** RL11 774400-10** RLV21 (in Q22 mode) 774440-76* DEQNA (#1-#2) (DELQA also?) 775000-176 DM11 (#1-#16) - DV11 (#1-#4) 775200-376 DN11-AA/DA (#1-#16) 775400-604* DS11 775400-576* LP20 775606 Reserved (0) 775610-6176 DL11 (#1-#31) 776200-60 DX11 (#1-#2) 776262-76 ? 776300-76 RH11/RH70 (alternate) 776400-76 AA11 (#2-#5) 776500-676 KL11/DL11 (#1-#16) - TU58 (#1-#16) 776700-52* RM03-5 - RP04-6 (RH11) 776710-36* RP11 (responds starting at 776700) 776754-66 AA11 (#1) 776770-2 AD01 776773-6 ? 777000-156 Reserved (0) 777160-6 CM11/CD11/CR11 777170-6 RX11/RX211 777200-76 Reserved (0) 777300-36 KE11 (#1-#2) 777340-56 TC11 777360-76 DC14-D 777400-16 RK11 777420-36 DT11 (#1-#8) 777440-76** RK611 777440-56* RC11 777460-76* RF11 777500-6* DIP11-A 777500-2* TA11 777510-2 Reserved (0) 777514-6 LP11/LS11/LV11 777520-4* BDV11 777520* Boot/Diagnostic Control (11/83) 777522* ROM Page Control (11/83) 777524* Boot/Diagnostic Configuration (read) / Display (write) (11/83) 777526 Reserved (0) 777530-6 XY11 777540-4 KV116-AA (typo for KU116-AA?) 777546 KW11-L/DL11-W/LTC/KPV11 777550-6 PC11/PR11 777560-6 Console KL11/DL11/DL11-W 777570 Console Switch (read) / Display (write) 777572 MMR0 777574% MMR1 777576 MMR2 777600-16 User I PDRs 777620-36% User D PDRs 777640-56 User I PARs 777660-76% User D PARs 777700-5 Registers (Set 0) 777706 KSP 777707 PC 777710-5 Registers (Set 1) 777716 SSP 777717 USP 777720-6 Reserved (1) 777730 Diagnostic Controller Status (11/84) 777732 Diagnostic Controller Data (11/84) 777734 Memory Configuration (11/84) 777736 Reserved (1) 777740-2 Error Address (11/70) 777744 Memory Error (11/70, /60, /44, /73) 777746 Cache Control (11/70, /60, /44, /73) 777750 Maintainence (11/70, /44, /73) 777752 Hit/Miss (11/70, /60, /44, /73) 777754 Cache Data (11/44) 777756 Reserved (1) 777760-2 System size (11/70) 777764 System I/D (11/70) 777766 System Error (11/70, /24, /44, /73) 777770 uProgram Break (11/70) 777772% PIR 777774 SLR (11/40, 11/45, 11/70) 777776 PS Sources: #0 - PDP-11 Processor Handbook (1981) #1 - PDP-11 Microcomputer Interfaces Handbook (1980) Notes: #0 - Per the appendix in the '76 11/70 and, '79-'80 PDP-11 Proc H'bks, the UNIBUS map is in 770200-366, not 200-372, but the '76 11/70 Proc H'bks say in the text (pg. 6-21) that it's 200-372.