North Star Horizon Help

From: Bob Stek <bobstek_at_ix5.ix.netcom.com>
Date: Thu Oct 8 10:46:27 1998

I have a manual for the N* HRAM series which I'd be happy to copy and send
you - email me. There are some differences between revision B and E boards
and there are lots of jumper options. In summary, S1 and S2 select the
active memory areas, JP1 selects the bank status on reset and selects I/O
control bits for bank switching and parity, JP2 selects areas to be bank
switched, JP3 selects the parity error response, JP4 implements the First
Quadrant option (only revision E 48K version), and JP6 is reserved (no
jumper).

Bob Stek
bobstek_at_ix.netcom.com
Saver of Lost SOLs (and the occasional Horizon)
Received on Thu Oct 08 1998 - 10:46:27 BST

This archive was generated by hypermail 2.3.0 : Fri Oct 10 2014 - 23:31:25 BST