Fun with the HX-20 battery pack

From: Brad Ackerman <bsa3_at_cornell.edu>
Date: Wed Jun 23 16:48:12 1999

I charged up the Epson HX-20 that I bought on Sunday, and it doesn't
seem to like me. The screen flickers out after a minute or so of use.
This seems to indicate a bad battery, but this hypothesis does not
appear to be borne out by lab tests.

Therefore, a lab report:

PURPOSE:
        To determine if the battery pack from subject computer is
        defective.

APPARATUS:
        Battery pack in question (4xsubC, 4.8V)
        Fluke 73-III handheld multimeter
        Hewlett-Packard 6060B DC electronic load
        Miscellaneous cables
        47-ohm and 100-ohm resistors

PROCEDURE:

        1. Measure open-circuit voltage of battery. Reading is 5.16
           VDC.

        2. Wire battery directly to load. Power on. Display reads
           5.14 VDC, 0.03 A. Load is set as follows:

                Range 6.0000 A
                Input Off (htf do you turn it on?)
                Short On (same)
                Tran Off
                Freq 1000
                Slew .50000
                Duty cycle 50.0
                Mode Current

        3. Dial in current at assorted amperages. Results:

                Current Actual
                requested (A) current (A) Voltage (VDC)
                0.000 0.03 5.14
                0.100 0.11 5.09
                0.150 0.16 5.08
                0.200 0.21 5.06
                0.250 0.26 5.04
                0.500 0.52 4.98
                1.000 1.00 4.98
                0.000 0.01 5.09

        4. Try some resistance values.

                Resistance (O) Current (A) Voltage (VDC)
                5000 -0.01 5.11
                1000 -0.01 5.11
                500 -0.01 5.11
                100 0.03 5.11
                50 0.08 5.09
                25 0.18 5.04
                10 0.48 4.98
                5 0.97 4.89

        5. Connect a resistor across the battery terminals, and measure
           the current.

                Resistor: 100 ohms (spec)
                                102.3 ohms (measured)
                Current: 47.3 mA

                Resistor: 47 ohms (spec)
                                46.3 ohms (measured)
                Current: 98.0 mA

CONCLUSION:

        This battery pack doesn't look too defective, although I really
        don't know too much about what the characteristics of a
        functioning pack are.


Could someone who knows these things tell me if this pack is indeed
okay, as these tests seem to indicate, or if it is indeed bad?

-- 
Brad Ackerman N1MNB      "...faced with the men and women who bring home
bsa3_at_cornell.edu          the pork, voters almost always re-elect them."
http://skaro.pair.com/                   -- _The Economist_, 31 Oct 1998
Received on Wed Jun 23 1999 - 16:48:12 BST