Now a UDA50 question...

From: Bill Pechter <pechter_at_pechter.dyndns.org>
Date: Sun Nov 14 19:23:46 1999

> The pattern is the same on both boards: 0 = off, 1 = on.

If you had the pattern below it calls out the M7162/7486

M7162 & M7161 = UDA50
M7486 & M7485 = UDA50A

      Error led MSD is the side to the front of the Ba11 (towards
the bottom of the boards.

      M7162 or M7486 M7161 or M7485

     \+-----------------+/ \+------------------+/
      | 8 4 2 1 | | 8 4 2 1 |
      | off on off on | | off on off on| this is
      | | | | the back of the ba11
front | | | |
of +-||--||--||--||--+ +-||--||--||--||---+
BA11-K

This points to a failure of the M7146 -- if the stuff is as I've
pictured. You seem to have them inverted -- or I misread your note.

Your pattern isn't documented as a valid failure code.

---
  bpechter_at_shell.monmouth.com|pechter_at_pechter.dyndns.org
      Three things never anger: First, the one who runs your DEC,
      The one who does Field Service and the one who signs your check.
Received on Sun Nov 14 1999 - 19:23:46 GMT