OT-ish : Centronics printer port timing

From: Pete Turnbull <pete_at_dunnington.u-net.com>
Date: Tue Jan 9 15:01:31 2001

On Jan 9, 18:35, Tony Duell wrote:
> I have a reasonable set of IBM Techrefs, and the timing for the 'IBM
> Graphics Printer' (a rebadged Epson MX80 or something like that) is much
> the same. In fact that's what I used as the 'standard' to design my
> interface. Of course what I'll discover too late is that the Epson timing
> (or that of other common printers like the Deskjet family) didn't
> actually have to be anything like that and that the authors of various
> OSes did something totally different that worked with common printers...

FWIW, the two assembly-language routines I can think of that used 7-bit
ASCII (one on a Z80 and one on a 6502) both did it by waiting for BUSY to
go false, then wrote (char AND 7FH) to the port, wrote (char OR 80H), wrote
(char AND 7FH) again, and exited. The eighth data bit was inverted and
used as the strobe.

-- 
Pete						Peter Turnbull
						Network Manager
						Dept. of Computer Science
						University of York
Received on Tue Jan 09 2001 - 15:01:31 GMT