RK07 repairable?

From: Jochen Kunz <jkunz_at_unixag-kl.fh-kl.de>
Date: Sun Jan 19 07:43:00 2003

On Sat, Jan 18, 2003 at 11:17:59PM +0000, Tony Duell wrote:

> That sounds like the 11/34 supply...
Ahh, can't wait for the machine to arrive. Uhh. Have to clear the
kitchen to make room for it this evening... :-)

> > > So they're not as dangerous to work on as most SMPSUs.
> > Well, I have a isolating transformer...
> For once you'll not need it.
I know. I spoke in general: If I had to use a isolating transformer,
I have one. There is that dead BA23 and SGI 4D35 PSU that I need to
repair also. It would be a good idea to use the isolating transformer
when doing this.

> > Hmm. I have no clue about SMPSUs. Good reason to learn more about them.
> These ones are _very_ simple,and use almost standard circuits.
Sounds promising.
-- 
tschüß,
          Jochen
Homepage: http://www.unixag-kl.fh-kl.de/~jkunz
Received on Sun Jan 19 2003 - 07:43:00 GMT