David V. Corbin schrieb:
> OK, I admit it...I am so confused...
it's easy to become confused with teletypes ;-)
> I have all of the documentation (I believe) is available from PDP8.net.
A fine starting point.
> I have carefully checked it out mechanically and (non-powered) electrically
> as best as I am able. The only question on this fromnt is one switch which
> appears to be out of position, but I can
> Not find a reference picture
> http://www.dynamicconcepts.us/Teletype/Switch1.JPG
Yes it is out of position.
Compare with "Figure 5 - Typing Unit" on Page 8 SECTION 574-122-702TC.
You can see the correct position in the FORM-OUT MECHANISM area.
The contacts are the INTERLOCK CONTACTS used for stopping the papertape
reader while doing a formfeed. (Only used in sprocket feed assemblies).
> What I can not seem to find the documentation for is the interconnection of
> the various Molex connectors:
> http://www.dynamicconcepts.us/Teletype/Cables1.JPG
You can get a pdf file from my website showing the wiring diagram for an
ASR33. This IMHO gives the best overview about the Molex connectors.
It is located at
http://pdp8.de/download/A3_KC5018.pdf
Hope this helps
Gerold
Received on Sun Apr 25 2004 - 12:59:03 BST