Monitor deflection magnets; what to do when one falls out & breaks?
I also wanted to point out one thing (just to be clear/pedantic)
There are several (5-6?) small (like 1/4" x 1/2") magnets glued in
random places around the yoke collar.
These are not, however, the ones I'm talking about. I'm talking about the
ones that are "cylinder magnets" in the "mmm" places below. They are all
about 2" long.
(hard to imagine why I would stoop to ascii art in this day of digital cameras)
viewed "through" the crt from the front:
-------------------
/ mmmmmmmmmmmmm \
/ mmmmmmmmmmmmm <------ this one fell out
|mm mm|
|mm mm|
|mm --- mm|
|mm / \ mm|
|mm \ / mm|
|mm --- mm|
|mm mm|
\ mmmmmmmmmmmmm /
\ mmmmmmmmmmmmm /
-------------------
Christopher McNabb wrote:
>On Thu, 15 Jul 2004 10:09:47 -0400, Brad Parker <brad_at_heeltoe.com> wrote:
>
>> But - the "tube" has broken into 3 pieces (it was broke when I found it.
>> honest). I carefully glued it back together (no glue in the joints,
>> however) and replaced it. This helped a little but did not cure the
>> problem.
>>
>
>A physical shock strong enough to break the magnet could easily have
>also reordered the magnetic domains, causing it to become less
>magnetic.
>