RK05 stuff (was RE: cctalk Digest, Vol 10, Issue 74)

From: Doc Shipley <doc_at_mdrconsult.com>
Date: Sat Jul 17 23:53:38 2004

Ashley Carder wrote:

> I've tried both of my RK05 drives. They power on fine. Blower
> seems to be fine. I put a pack in, press the run switch. The
> motor never comes on that turns the drive. The same thing
> happens in both drives. Neither drive will start spinning at
> all.
>
> Any ideas on where to start looking?

   Is the PSU input voltage right? I picked up an RA60 drive at
Christmas that had been set for 250VAC, and it behaved exactly like that
on a 110VAC circuit.

   I don't know if the RK05 is switchable or not; just an idea.


        Doc