IBM 3101 Dip Switches Configuration
On Thu, 24 Jan 2002, SP wrote:
> The problem is that the IBM 3101 don't establish communication
> with the Linux system. The 3101 show one "Line Check 2" message
> that talk about the comm.line, I suppose. The cable used is one
> normal serial cable.
If by "normal serial cable" you mean a standard port-to-modem cable,
that is most likely your problem. You need to use a null-modem serial
cable with a terminal.
Doc
Received on Thu Jan 24 2002 - 17:14:42 GMT