> What I can not seem to find the documentation for is the interconnection of
> the various Molex connectors:
> http://www.dynamicconcepts.us/Teletype/Cables1.JPG
Do you mean the 15 pin ones at the back of the call control unit? The
cable-mounted plugs should all be numbered, the sockets are in 2 rows of
4, 1 to 4 (left to right looking from the back of the machine) in the top
row, 5-8 in the bottom row. Many won't actually be used.
IIRC, 3 is the motor, receive magnet, etc connetor, 8 goes to the
distributor disk, 6 and 7 are keyboard and reader (I forget which way
round). And on a lot of of machine they're keyed so you can't get them in
the wrong places.
There will also me a socket on a fairly long cable. This connects to the
Reader PSU, often moutned at the top of the stand, not in the main part
of the teletype.
>
> If anyone could spare some time to help walk me through getting this safely
> powered up, I would be very grateful.
If it turns freely by hand, give it 115V, turn the frontpanel switch to
'Local' (assuming the normal private-line call control unit) and see what
happenes
-tony
Received on Sat Apr 24 2004 - 16:18:36 BST